I N S TA L L A TI O N I N S T R U C TI O N S
The Telephone Input Module Wiring
4.18
Aud
Utl
Cue
Off
line
Pgm
Phone
1
2
3
4
5
6
7
8
Talk
Tally
Channel Off
Ground
Stop Logic
Channel On
Logic common
Start Logic
Logic
1
2
3
4
5
6
7
8
(+) out
(-) out
nc
Ground
nc
nc
nc
nc
Phone module out
1
2
3
4
5
6
7
8
(+) in
(-) in
nc
Ground
Stop Logic
nc
Logic common
Start Logic
Phone module In
3) Phone Input module (MARC-PHN)
PHONE MODULE NOTE:
The logic controls (1) Stop Logic,
(2) Start Logic, and (3) Logic com-
mon are momentary closures from
a dry contact reed relay (max cur-
rent = 50 milliamps). They are avail-
able on the ‘Phone module in’ and
‘Logic’ connectors for connection to
the hybrid.
Start logic
Common
Stop Logic
a) CONSOLE PHONE INPUT- A telephone hybrid has an audio input and an audio output. The hybrid audio
output is the callers voice and is connected to the input on the phone module.
b) CONSOLE MIX MINUS OUTPUT
- The input to the hybrid is from the console PHONE OUT connector on the
back of the module. A mix minus bus is a special audio mixing bus that contains all audio on the console bus
MINUS the callers voice. In this way the caller hears everything except himself. If he was not “minused”
from the mix, then the caller would feed back to himself.
c) CONTROL LOGIC
- The hybrid has two ways to “answer” the caller and pick up the telephone line: front
panel manual control of the hybrid itself and remote control. For manual control, an On and Off button will be
located on the front panel of the hybrid. For remote control, the PHONE LOGIC module connector (RJ45)
must have a custom cable connecting it to the console source start/stop logic. The logic is dry reed relay
closures for both Start and Stop as shown below.
d) CALIBRATION
- The console PHONE IN and PHONE OUT connectors are set for +4dBu levels. These connec-
tors have trim pots on the top of the module
Input
trim
Output
trim
Connectors
Logic Out In
PIN Wire Color Audio
1 White w/Orange Stripe Left (+)
2 Orange w/White Stripe Left (-)
3 White w/Green Stripe Right (+)
4 Blue w/White Stripe Ground
5 White w/Blue Stripe
6 Green w/White Stripe Right (-)
7 White w/Brown Stripe
8 Brown w/White Stripe
1,2,3,4,5,6,7,8
RJ45
EIA/TIA 568B WIRING STANDARD COLORS
IMPORTANT
Two phone modules can be
placed in a single mainframe.
They are...
1) MARC-PHN1
2) MARC-PHN2
Two PHN1s or two PHN2 mod-
ules should not be used in the
same mainframe
Vue de la page 45